ClarkWestern

How to Specify ClarkWestern

How to Specify ClarkWestern and ClarkWestern’s Products
in your Architectural Specifications:

 

Specifying ClarkWestern ProSTUD™ & ProTRAK™
Drywall Framing System

 

 

 

 

 

1.X   QUALITY ASSURANCE

  1. Fire-Test-Response Characteristics: For fire-resistance-rated assemblies that incorporate non-structural steel framing, provide materials and construction identical to those tested in assembly indicated according to ASTM E119 by an independent testing agency. Products used in the assembly shall carry a classification label from Underwriters Laboratories (UL).

    (Retain paragraph below where framing is part of STC-rated assemblies.
    Indicated design designations of specific assemblies on Drawings.)

  2. STC-Rated Assemblies:  For STC-rated assemblies, provide materials and construction identical to those tested in assembly indicated according to ASTM E90 and classified according to ASTM E 413 by an independent testing agency.

2.3   COMPONENTS

  1. Non-structural Studs: Cold-formed galvanized steel C-studs, ClarkWestern ProSTUD™ drywall studs, in conformance with ASTM C-754 for conditions indicated below:
    1. Flange Length: 1 1/4 inch (32mm) 125 flange.
    2. Web Depth: As indicated on drawings.
    3. Designation: ProSTUD 25 (25ga equivalent drywall stud) 70ksi
      Minimum Thickness: 0.0150 inches (0.3810mm)
      Minimum Design Thickness: 0.0158 inches (0.4013mm)

    4. Designation: ProSTUD 22 (22ga equivalent drywall stud) 70ksi
      Minimum Thickness: 0.0179 inches (0.4547mm)
      Minimum Design Thickness: 0.0188 inches (0.4775mm)

    5. Designation: ProSTUD 20 (20ga equivalent drywall stud) 65ksi
      Minimum Thickness: 0.0220 inches (0.5588mm)
      Minimum Design Thickness: 0.0232 inches (0.5893mm)

      For additional ProSTUD thicknesses to meet nonstandard specifications
      see: www.clarkwestern.com/ProSTUD-HomePage.php
    6. Members that can show certified third party testing in accordance with ICC-ES-AC86 (Approved July 1995—Editorially Revised September 2005) and conform to the limiting height tables in Specification C 754 need not meet the minimum thickness limitation set forth in 4.3 or the minimum section properties set forth in 8.1.
  2. Non-structural Track: Cold-Formed galvanized steel runner tracks, ClarkWestern ProTRAK™ drywall track, in conformance with ASTM C-754 for conditions indicated below:
    1.          Flange Length: 1 1/4 inch (32 mm) T125 flange.
    2.          Web Depth: Track web to match stud web size.
    3.          Minimum Material Thickness: Track thickness to match wall stud thickness.