How to Specify ClarkWestern
How to Specify ClarkWestern and ClarkWestern’s Products
in your Architectural Specifications:
Specifying ClarkWestern UltraSTEEL®
1.X QUALITY ASSURANCE
- Fire-Test-Response Characteristics: For fire-resistance-rated assemblies that incorporate non-structural steel framing, provide materials and construction identical to those tested in assembly indicated according to ASTM E119 by an independent testing agency. Products used in the assembly shall carry a classification label from a testing laboratory acceptable to authority having jurisdiction.
(Retain paragraph below where framing is part of STC-rated assemblies.
Indicated design designations of specific assemblies on Drawings.)
- STC-Rated Assemblies: For STC-rated assemblies, provide materials and construction identical to those tested in assembly indicated according to ASTM E90 and classified according to ASTM E 413 by an independent testing agency.
2.3 COMPONENTS
- Non-structural Studs: Cold-formed galvanized steel C-studs, ClarkWestern UltraSTEEL® drywall studs, in conformance with ASTM C-754 for conditions indicated below:
- Flange Length: 1 1/4 inch (32mm) 125 flange.
- Web Depth: As indicated on drawings.
- Designation: 25ga equivalent drywall stud.
Minimum Delivered Thickness: 0.0179 inches (0.45mm)
- Designation: 20ga equivalent drywall stud.
Minimum Delivered Thickness: 0.0296 inches (0.75mm)
- Members that can show independently verified test performance that meets the limiting height values listed in C 754 (need not meet the minimum thickness set forth in 4.3 or the minimum section properties set forth in 8.1).
- Non-structural Track: Cold-Formed galvanized steel runner tracks, ClarkWestern UltraSTEEL® drywall runner track, in conformance with ASTM C-754 for conditions indicated below:
- Flange Length: 1 1/4 inch (32 mm) T125 flange.
- Web Depth: Track web to match stud web size.
- Minimum Material Thickness: Track thickness to match wall stud thickness.